A Facility Manager’s Introduction To Weather Correction For Utility Bill Tracking


0
Categories : Accounting Firm

By John Avina

ABSTRACT

Utility bill tracking is at the heart of an effective energy management program. Merely comparing utility bills can yield inaccurate indications of the amount of savings from energy management programs due to the unaccounted influence of weather or other factors. Correcting utility bills for weather data will give more accurate representations of savings that were accrued. This paper presents the how and why of weather correction for those who want to become more familiar with the concepts and methodology.

WHAT UTILITY BILL TRACKING CAN DO FOR YOU

Jim Faes from Jefferson County School District wrote to me “energy accounting is the backbone of our school district’s energy management program.” Why would he write that?

An energy accounting system is much like an airplane’s control panel. In order to correctly navigate your airplane, you need to understand where it is, where it was and where it is going. If you fly the plane without the control panel, you have a good chance of crashing the plane. It is the same with energy management. You need to know where you are, where you were, where you are going, and how where you are now fits with expectations of your progress.

With utility bill tracking systems, Energy managers can:

– Enter target usage and costs and track their actual performance against their targets

– Discover large increases in energy usage and take corrective actions

– Identify the buildings that are using more $/SQFT than the others, and concentrate energy management activities on those buildings.

– Determine whether your meters are on the best rates

– Check to see if you are being billed correctly by the utility

– Create bills for your tenants (if you have any)

– Determine whether you have saved any energy from your energy conservation measures

– Aggregate your usage and costs and pass this aggregated data to potential energy suppliers

– Create utility budgets

[youtube]http://www.youtube.com/watch?v=lZEwS1Gsmk4[/youtube]

More generally, if you keep aware of the state of your utility accounting, you will know where your facility is and how it is faring towards your goals.

UTILITY BILL TRACKING: THE REPORT CARD FOR FACILITIES AND FACILITY MANAGERS

Energy Managers and some Facility Managers all to often have to justify their existence to management. How much did we save last year? Is that more than what we pay our energy manager? Did your recommendations give reasonable paybacks? Why do we even have an energy manager?

There are several methods to determine whether you have saved energy from your energy conservation efforts, as described in the literature. You can wave your hands in the air, and decide upon a number; calculate your savings based upon data logger and control points; compare utility bills to determine savings; and finally, employ a building model. (These are referred to as Option A, B, C and D in the IPMVP, FEMP Guidelines and other literature.)

Most likely, the simplest and most palatable method for the facility manager to determine whether you are saving energy is Option C, comparing utility bills. Why? Well, although some utility managers do present calculations given to them by the friendly sales rep, this method is hardly reliable, as they may produce inflated numbers. Placing dataloggers and using existing control points seems easy enough, but converting these inputs into savings numbers can sometimes prove to be outside of the scope of the facility manager’s skillset. Building modeling, while it can be useful, requires hours of time to construct the model, and may represent how much the building should be using, and may not really represent what the building truly is using. If those objections hold, that leaves utility bills as the last remaining method to quantify your performance as an energy manager. Plus, in the end, it is all about the utility bills, as the bills reflect how much you are paying.

Since most facility managers are already tracking their utility bills, it is only one additional small step to see whether you have saved any energy and costs from your energy management program. Just compare prior year bills to current year’s bills, and you will see if you have saved.

Well, it isn’t that easy. Let’s find out why.

HOW WEATHER CORRECTION WORKS

Rather than compare last year’s usage to this year’s usage, when we use weather correction, we compare how much energy we would have used this year to how much energy we did use this year. Many in our industry do not call the result of this comparison, Savings, but rather Usage Avoidance or Cost Avoidance. But, since we are trying to keep this paper at an introductory level, we will use the word Savings.

When we tried to compare last year’s usage to this year’s usage, we saw Figure 3, and a disastrous project. We used the equation:

Savings = last year’s usage – this year’s usage

When we use weather correction, we end up with Figure 5, and use the equation:

Savings = How much energy we would have used this year – how much energy we did use this year**

**where this year’s usage from the 1st equation is the same as how much energy we did use this year from the 2nd equation

The next question is, how do we figure out how much energy we would have used this year. This is done using weather correction as shown below.

First, we select a year of utility bills we want to compare future usage to. This would typically be the year before you started your energy efficiency program, or the year before you, the new facility manager, were hired, or some chosen year. In this example, we would select the year of utility data before the installation of the chilled water system. We will call this year the Base Year.

As shown in Figure 6, we graph Base Year usage versus weather (in the form of Cooling Degree Days or Heating Degree Days). The blue dots represent the utility bills.

Then we find the Best Fit Line between usage and weather. The Best Fit Line is the line that comes closest to all the utility bills as shown in Figure 6. We can tell it is the Best Fit Line by looking at some statistical indicators (such as R2 value, Net Mean Bias Error and CVRMSE, which are not covered in this introductory paper) .

This Best Fit Line has an equation, which we call the Fit Line Equation, or in this case the Baseline Equation. Once we have this equation, we are done with this regression process.

Let’s recap what we have done:

– We graphed a Base Year of utility data versus weather data

– We found a Best Fit Line through the data. The Best Fit Line then represents the utility bills.

– The Best Fit Line Equation, which represents the Best Fit Line, which in turn represents the Base Year of utility data. The Fit Line Equation represents how your facility used energy during the Base Year, and would continue to use energy in the future (varying with changing weather conditions) assuming there were no significant changes occurred in building consumption patterns, such as new equipment, area or operating hours.

Base Year bills – Best Fit Line = Fit Line Equation

In our example:

Baseline Equation = Fit Line Equation

Once you have the Baseline Equation, you can determine if you saved any energy.

How? You take a bill from some billing period after the Base Year. You (or your software) plug in the number of days and the number of degree days from the bill into your Baseline Equation. Remember, the Baseline Equation represents how your building used to use energy in the Base Year. So, with the new inputs of number of days and number of degree days, the Baseline Equation will tell you how much energy the building would have used this year based upon Base Year usage patterns and this years conditions (weather and number of days). We call this usage that is determined by the Baseline Equation, Baseline Usage.

Now, to get a fair comparison of this year versus last year, we compare:

Savings = How much energy we would have used this year – How much energy we did use this year

or if we change the terminology a bit:

Savings = Baseline Energy Usage – Actual Energy Usage

where Baseline Energy Usage is calculated using the Baseline Equation and current month’s weather and number of days, and Actual Energy Usage is the current month’s bill. Both equations are one and the same, Baseline = How much energy we would have used this year, and Actual represents how much energy we did use this year.

CORRECTING FOR OTHER VARIABLES

Facility Managers in the industrial sector may want to correct for production rather than (or in addition to) weather data. This works if you have a simple variable that quantifies your production. For example, an automobile manufacturing plant can track number of automobiles produced. If your factory makes several different things, for example, disk drives, desktop computers, printers and main frame computers, it is difficult to come up with a single variable that could be used to represent production for the entire plant. However, if your printer manufacturing unit was served by a different meter or submeter than the other units, then you could use the number of printers produced as a variable for the meter (or submeter) that serves the printing unit.

WEATHER CORRECTION IN EXCEL VS. CANNED SOFTWARE

Weather correction can be done in Excel, however it can be laborious, and oftentimes may not be as rigorous as when done using specialized software. Excel will give regressions, fit line equations, and statistical indicators which show how well your usage is represented by the fit line. However, it is difficult to find the best balance point in Excel, as you can in specialized software. Excel may force you have to choose just one balance point, and possibly then you would iterate with different balance points, whereas canned software will allow you to easily find the best fit line using different balance points. In addition, if you enter your weather data in high low temperatures or average temperatures, it can be difficult to apply the correct weather data to the correct billing periods. Try it, and you will see.

AVAILABLE WEATHER CORRECTION DESKTOP SOFTWARE

All of the major desktop utility bill tracking software packages will now correct for weather data. Nearly all of them will correct for your own variables as well. The major desktop programs are Energy CAP, Metrix, Stark Essentials, and Utility Manager Pro. You can find information on all of them online.

CONCLUSION

Weather changes from year to year. If wish to use utility bills to show energy savings from energy management programs with any degree of accuracy, it is important to correct your utility bills for fluctuations in weather.

About the Author:

Abraxas Energy Consulting

performs commercial

energy audits

and provides utility bill tracking, energy auditing, measurement and verification, retro-commissioning, utility bill auditing and other energy management services for its clients world-wide.

Source:

isnare.com

Permanent Link:

isnare.com/?aid=394115&ca=Computers+and+Technology